Difference: ATF2BDSIMDetectors (1 vs. 5)

Revision 515 Feb 2016 - LaurieNevay

Line: 1 to 1
 
META TOPICPARENT name="ATF2201506visit"
Line: 30 to 30
 

META FILEATTACHMENT attachment="Tapered_beam_pipe.pdf" attr="" comment="drawing collimator" date="1434293569" name="Tapered_beam_pipe.pdf" path="Tapered_beam_pipe.pdf" size="501425" user="uxap001" version="1"

Revision 415 Feb 2016 - LaurieNevay

Line: 1 to 1
 
META TOPICPARENT name="ATF2201506visit"
Line: 26 to 26
 
  • front to PMT: 70 cm
  • lead front: 5x5cm , 3mm depth
Added:
>
>
<--

Settings just to customise this page

-->
 
META FILEATTACHMENT attachment="Tapered_beam_pipe.pdf" attr="" comment="drawing collimator" date="1434293569" name="Tapered_beam_pipe.pdf" path="Tapered_beam_pipe.pdf" size="501425" user="uxap001" version="1"

Revision 315 Jun 2015 - JsnuverinkSnuverink

Line: 1 to 1
 
META TOPICPARENT name="ATF2201506visit"
Line: 14 to 14
 
  • head depth (to first angle): 5 cm
  • straight: 30 cm
  • front to PMT: 57 cm
Added:
>
>
  • lead front: 5x5cm , 3mm depth
 
Changed:
<
<
Detector 2
>
>
Detector 2 (after QF9AFF and SK4FF)
 
  • Hamamatsu PMT R877
  • PMT in nu-metal box
Added:
>
>
  • 90 mm diameter aperture to PMT (needed for construction and protection of PMT)
 
  • aerogel: same as detector 1, 5 slices, 5x4cm, 5 cm deep
  • light pipe 10 cm^2
  • head depth: 19 cm
  • front to PMT: 70 cm
Changed:
<
<
  • 90 mm diameter aperture to PMT (needed for construction and protection of PMT)
>
>
  • lead front: 5x5cm , 3mm depth
 
META FILEATTACHMENT attachment="Tapered_beam_pipe.pdf" attr="" comment="drawing collimator" date="1434293569" name="Tapered_beam_pipe.pdf" path="Tapered_beam_pipe.pdf" size="501425" user="uxap001" version="1"

Revision 214 Jun 2015 - JsnuverinkSnuverink

Line: 1 to 1
 
META TOPICPARENT name="ATF2201506visit"

Detectors

Deleted:
<
<
  • Hamanatsu PMTs 688
 
Added:
>
>
Detector 1 (laserwire location)
 
Added:
>
>
  • Hamamatsu PMTs, same as old laserwire one
  • PMT in nu-metal box
  • aerogel: SP15, index 1.015, 4 slices, 4 cm^2, 5 cm deep
  • light pipe 10 cm^2
  • head depth (to first angle): 5 cm
  • straight: 30 cm
  • front to PMT: 57 cm
 
Deleted:
<
<
-- LaurieNevay - 13 Jun 2015
 \ No newline at end of file
Added:
>
>
Detector 2
  • Hamamatsu PMT R877
  • PMT in nu-metal box
  • aerogel: same as detector 1, 5 slices, 5x4cm, 5 cm deep
  • light pipe 10 cm^2
  • head depth: 19 cm
  • front to PMT: 70 cm
  • 90 mm diameter aperture to PMT (needed for construction and protection of PMT)

META FILEATTACHMENT attachment="Tapered_beam_pipe.pdf" attr="" comment="drawing collimator" date="1434293569" name="Tapered_beam_pipe.pdf" path="Tapered_beam_pipe.pdf" size="501425" user="uxap001" version="1"

Revision 113 Jun 2015 - LaurieNevay

Line: 1 to 1
Added:
>
>
META TOPICPARENT name="ATF2201506visit"

Detectors

  • Hamanatsu PMTs 688

-- Public.LaurieNevay - 13 Jun 2015

 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2021 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding RHUL Physics Department TWiki? Send feedback