20130225 Nonlinear Scan Optimisation
Line: 47 to 44
It seems important to have a few points close together at the top incase you miss the middle when specifying where the centre of the scan should be.
But you also want more points closer together down the sides.
Added:
>
>
Version 3
single point in specified centre: then considering points only to the positive side for now (simply flip for others)
so 50 points + 1 for centre -> 25 either side:
step size 0.3um for 2 points
step size 0.7um for 10 points
step size 1.5um for 5 points
step size linearly increases for remaining 7 points from 2um to 10um