META TOPICPARENT |
name="NewClicBpm" |
Reference Cavity |
|
S22 |
14.772 |
1313 |
3283 |
938 |
938 |
- The unloaded Q factor is higher than before brazing, however the external Q is larger, making the Q factor larger than 500.
|
|
> > |
- Need to simulate to determine why the external Q factor is high, what can be done to correct this.
|
|
Position Cavity |
|
S33 |
14.996 |
1200 |
2222 |
779 |
779 |
S44 |
14.995 |
1394 |
2221 |
857 |
857 |
|
|
< < |
- The external Q is not as higher as before but still much larger than the value in simulation, ~600.
|
> > |
- The external Q is not as high as before but still much larger than the value in simulation, ~600.
- Need to simulate to determine why the external Q factor is high, what can be done to correct this.
|
|
Cross Coupling |
|
Maximum Signal /dB |
-43.9 |
-51.1 |
-44.3 |
-48.6 |
- All maximum cross couplings are below -40 dB.
|
|
> > |
- Much lower (remarkably lower) than measured previously.
|
|