Line: 54 to 54
 
GdfidL 50.3 118
Ace3p 50.7 118
Added:
>
>
Position signal (offset=1mm, charge=1nC) Reference signal (Charge=1nC)
Location Volts dBm Volts dBm
Cavity out 14.7 36.4 118 54.4
Electronics in 3.37 23.6 5.39 27.6
Electronics out 5.99 9.60 9.2 32.6
Digitiser in 4.44 26.0 7.11 30.0

  • Position scale factor: 0.62 mm
 
 