Days, Calendar Created: 24 Sep 2013 16:55:51 Days, Calendar Last Revised: 25 Sep 2013 18:23:27 Person PedroPaiva Text Focus Study (Pt I)
Line: 29 to 29
 
  • move(-1000) - 0.44mm
  • move(-1000) - 0.27mm
  • move(-1000) - 0.45mm
Changed:
<
<
  • mean = (0.378 ▒ 0.076)
>
>
  • mean = (0.378 ▒ 0.076)mm
  The out movement is coherent and 5000 steps is indeed equivalent to 5x1000 steps
This give 1 step aprox 0.37Ám

Line: 40 to 40
 
  • move(5000) - 1.52mm
  • move(5000) - 1.48mm
  • move(5000) - 1.57mm
Changed:
<
<
  • mean = 1.528 ▒ 0.031
>
>
  • mean = (1.528 ▒ 0.031)mm
 
  • move(1000) - 0.21mm
  • move(1000) - 0.20mm
  • move(1000) - 0.15mm
  • move(1000) - 0.30mm
  • move(1000) - 0.18mm
Changed:
<
<
  • mean = 0.208 ▒ 0.050
>
>
  • mean = (0.208 ▒ 0.050)mm
  The in movement is 25 to 50% smaller than the out movement (depending on the movement size) with larger movements closer to the equivalent out.
This give 1 step being between 0.2 and 0.3Ám

Revision 224 Sep 2013 - PedroPaiva

Line: 1 to 1
 
META TOPICPARENT name="LogBookAstronomy"

Log Book Entry No.15

Days, Calendar Created: 24 Sep 2013 16:55:51 Days, Calendar Last Revised: 25 Sep 2013 18:23:27 Person PedroPaiva Text Focus Study (Pt I)
Line: 8 to 8
 Please DO NOT alter or remove the line above this line. -->
Changed:
<
<
Testing..., I could create and edit this logbook entry OK
>
>
Focus movements
  • Positive -> In
  • Negative -> Out
 
Changed:
<
<
Tom.
>
>
Tests
The data below have a significant experimental error associated with the not fixed measuring equipment.
Also, they can have errors related to a possible angle between the measuring equipment and the in-out axis therefore, the real value would differ by a factor of cos(theta)

out

  • move(-5000) - 1.86mm
  • move(-5000) - 1.80mm
  • move(-5000) - 1.86mm
  • move(-5000) - 1.81mm
  • move(-5000) - 1.88mm
  • mean = (1.842 ▒ 0.031)mm

  • move(-1000) - 0.31mm
  • move(-1000) - 0.40mm
  • move(-1000) - 0.44mm
  • move(-1000) - 0.27mm
  • move(-1000) - 0.45mm
  • mean = (0.378 ▒ 0.076)

The out movement is coherent and 5000 steps is indeed equivalent to 5x1000 steps
This give 1 step aprox 0.37Ám

in

  • move(5000) - 1.52mm
  • move(5000) - 1.55mm
  • move(5000) - 1.52mm
  • move(5000) - 1.48mm
  • move(5000) - 1.57mm
  • mean = 1.528 ▒ 0.031

  • move(1000) - 0.21mm
  • move(1000) - 0.20mm
  • move(1000) - 0.15mm
  • move(1000) - 0.30mm
  • move(1000) - 0.18mm
  • mean = 0.208 ▒ 0.050

The in movement is 25 to 50% smaller than the out movement (depending on the movement size) with larger movements closer to the equivalent out.
This give 1 step being between 0.2 and 0.3Ám

Conclusions
The execution of the above movements led to the following conclusions:

  • Focuser always finishes in a 'in-movement' (e.g. asking to move out will make the focuser goes more than needed and come back about 1mm)
  • This causes the isMoving check to return before the focus being ready.

  • Focuser limit less than aprox 30k steps when going in.
  • When close to the limit, focuser will overstep (move(5000) caused the focuser to move 2.76mm)

  • Focuser isn't ready when isMoving returns False.
  • There's a time gap when a second comand will be accepted but not executed.
  Back to: LogBookAstronomy

META FORM name="%25SYSTEMWEB%25.LogBookForm"
Changed:
<
<
FORM FIELD Subject Subject logbook problem test
FORM FIELD Status Status led-green
FORM FIELD Author Author TomCraneAdmin
>
>
FORM FIELD Subject Subject Focus Study (Pt I)
FORM FIELD Status Status blank
FORM FIELD Author Author PedroDeCarvalhoPaiva

Revision 124 Sep 2013 - TomCraneAdmin

Line: 1 to 1
Added:
>
>
META TOPICPARENT name="LogBookAstronomy"

Log Book Entry No.15

Days, Calendar Created: 24 Sep 2013 16:55:51 Days, Calendar Last Revised: 25 Sep 2013 18:23:27 Person PedroPaiva Text Focus Study (Pt I)

<-- 
Please DO NOT alter or remove the line below this line. 
  • Set EDITMETHOD = wysiwyg
Please DO NOT alter or remove the line above this line. -->

Testing..., I could create and edit this logbook entry OK

Tom.

Back to: LogBookAstronomy

META FORM name="%25SYSTEMWEB%25.LogBookForm"
FORM FIELD Subject Subject logbook problem test
FORM FIELD Status Status led-green
FORM FIELD Author Author TomCraneAdmin
 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2021 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding RHUL Physics Department TWiki? Send feedback