27-09-2017

  • Baseline Analysis,
    • Initially performed my own baseline extraction in order to learn a few things about the raw TFile structure
    • Rewrote the same analysis in the space of a few hours using the dmtpc framework
  • Process is to,
    • Extract the baseline from every trace and push it into a histogram for each channel
    • Fit gaussian/find RMT and define a cut of accepting only waveforms that have a baseline within 8sigma
    • Remove whole events that do not make the cut, Replot and refit.
  • BaseLines_bfandaf.png
  • Pulse height analysis
    • dmtpc framework is mostly defined in Pulse.hh (for anyone who is interested)
    • The getPeak() function extracts the peak and subtracts for baseline offset
    • Further acceptance can be performed based on getPeakTime()
    • Code (and a tutorial on what each part of my macro is doing what has been passed down to Adriana for further modification/development (getPeakTime() cuts which shouldn't take much development
    • Currently my analysis works only one a single file though it should be realitively simple to make it work on a string of files.
    • Quite slow... might concider a compiled version rather than a macro, shakes fist at CINT
  • PeakHeights.png
  • PeakHeights_Cut.png
  • Friday - Adriana and I did a full vacuum system and DMTPC operations tutorial,
    • Made modification to HV feedthrough, changing the connection type to a push on one
    • Applied Kapton insulation over any bare wire, the push on connector and length of the pin.
    • Proved the HV feedthrough operates up to the full capacity of the supply (8kV) in Nitrogen, no sparks or issues
    • Evacuuated vessel
  • Started Testing performance of the Cremat boards, Initially tests look like boards are healthy, but we have devised a full set of tests to be performed in order to check board health and operation of different Amps in each
  • Should be completed in next couple of days, if all checks are good we move onto the grounding and backfill the detector for sample runs

META FILEATTACHMENT attachment="BaseLines_bfandaf.png" attr="" comment="" date="1506512347" name="BaseLines_bfandaf.png" path="BaseLines_bfandaf.png" size="97136" user="udap005" version="1"
META FILEATTACHMENT attachment="PeakHeights.png" attr="" comment="" date="1506512354" name="PeakHeights.png" path="PeakHeights.png" size="37671" user="udap005" version="1"
META FILEATTACHMENT attachment="PeakHeights_Cut.png" attr="" comment="" date="1506512981" name="PeakHeights_Cut.png" path="PeakHeights_Cut.png" size="16043" user="udap005" version="1"

Revision 127 Sep 2017 - MarkWard

Line: 1 to 1
Added:
>
>
META TOPICPARENT name="MarkWard"
-- MarkWard - 27 Sep 2017

Previous Logbook

 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2022 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding RHUL Physics Department TWiki? Send feedback