Tags:
create new tag
view all tags

Plan

  • Focus scan
  • Rotation scan
  • Lens vertical scan
  • Iris scan
  • Quad Scan
  • Filter scan

  • Different binning
  • Different lens side

  • Final quad scan

20:05 Start

  • beam tuning
  • load optics: set13mar01_1357.dat
  • Initial Parameters:

binning 3x3

otrlensz 13.5

otrm1x 4.2

otrm1y 3.6

otrlensy 5.5

otr_iris 26.184

charge 0.6 *10^10

filter 4 (550-40)

Lens CVI LAO - 120 - 30

  • Magnification factor

Lens Magnification Factor
CVI LAO 120 30 7.40
DLB 30 100 PM 9.19
BLB 30 120 PM 7.39
SLB 30 100 PY2 9.13

* First image (without filter):

first_image.jpg

Focus scan

  • Start: 10, stop: 13, step: 0.5

Super good result but not enough resolution -> change binning to 3x1

  • repeat focus scan, start from 11, to 11.7 with 0.07 mm step
  • Best focus position: 11.35

  • Image in focus:

focus_image.jpg

Quad scan

  • QM14FF Initial current: -91.92 A
  • Start: -85, stop: -95, step: 1 A
  • Best position: 91.78
  • sigma: 1.50 +- 0.037

q-scan.png

Iris scan

  • Start: 26.184, stop: 5.800, step: 1.568 mm

Filter scan

Many modulator trigger interlocks

Rotation scan

  • Initial 2.13
  • Start: -4, stop: 8, step: 1
  • Set rotation angle to the initial value

Lens DLB-30-120-PM

Do the same set of scans

Focus scan

  • Start: 11.6, stop: 12.6 , step: 0.1
  • Focus position: 12.1 mm

  • Image in focus:
focus.jpg

Lens vertical scan

  • start: 4.5, stop: 7, step 0.5 return to 5.5 mm
  • take 10 images at focus lens position = 12 mm.
  • move otr:lens:z lens vertically to 7mm and take 10 images
  • move otrm1y from 3.6 to 4

Quad scan

  • Initial current = 91.74
  • Start: -85, stop: -96, step: 1 A
  • Best position: 92.05
  • sigma: 1.12 +- 0.038

quad_scan.png

Iris scan

  • Start: 26.184, stop: 5.800, step: 1.568 mm

Filter scan

2D Filter scan (i.e. focusing scans for different filters):

  • Focus scan 550 40
  • Focus scan 500 40
  • Focus scan 500 25
  • Focus scan 550 25
  • Focus scan 600 40

Lens DLB-30-100-PM

Focus scan

  • Start 11.11, stop: 11.27, step: 0.02
  • Focus position: 11.19

  • Image in focus:
focus.jpg

Quad scan

  • Initial current = 91.76
  • Start: -88, stop: -97, step: 1 A
  • Best position: 91.73
  • sigma: 1.24 +- 0.075

quad_scan.png

Iris scan

  • Start: 26.184, stop: 5.800, step: 1.568 mm

Filter scan

Lens SLB 30 100 PY2

Focus scan

  • Start: 8.9, stop: 9.6, step: 0.1
  • Focus position: 9.19

Focus Scan Image in Focus
focus_scan.png focus.jpg

Quad scan

  • change binning to 3x3 due to low signal to noise
  • Initial current = 91.66
  • Start: -88, stop: -97, step: 1 A
  • Best position: 93.20
  • sigma: 1.75 +- 0.10

quad_scan.png

set file : set13mar05_0839.dat

Topic attachments
I Attachment History Action Size Date Who Comment
JPEGjpg first_image.jpg r1 manage 1143.3 K 05 Mar 2013 - 08:43 KonstantinKruchinin  
JPEGjpg focus.jpg r3 r2 r1 manage 46.2 K 11 Mar 2013 - 06:05 KonstantinKruchinin  
JPEGjpg focus_image.jpg r1 manage 33.7 K 11 Mar 2013 - 05:44 KonstantinKruchinin Focused Image
PNGpng focus_scan.png r2 r1 manage 46.6 K 06 Mar 2013 - 02:29 KonstantinKruchinin  
PNGpng q-scan.png r1 manage 48.9 K 05 Mar 2013 - 09:06 KonstantinKruchinin  
PNGpng quad_scan.png r3 r2 r1 manage 55.8 K 06 Mar 2013 - 04:07 KonstantinKruchinin  
Edit | Attach | Watch | Print version | History: r9 < r8 < r7 < r6 < r5 | Backlinks | Raw View | Raw edit | More topic actions

Physics WebpagesRHUL WebpagesCampus Connect • Royal Holloway, University of London, Egham, Surrey TW20 0EX; Tel/Fax +44 (0)1784 434455/437520

Topic revision: r9 - 11 Mar 2013 - KonstantinKruchinin

 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2023 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding RHUL Physics Department TWiki? Send feedback