Tags:
create new tag
view all tags

2009/02/24

Calibration of QM16FF (phase unstable):

x:bpmMovercal2009_2_24__7_57_21.mat

y:bpmMovercal2009_2_24__8_0_11.mat

Calibration of QM16FF (phase stable):

x:bpmMovercal2009_2_24__8_3_18.mat (stable)

y:bpmMovercal2009_2_24__8_4_34.mat (stable for first 1/2 of run)

Calibration of QD6FF:

x:bpmMovercal2009_2_24__8_22_2.mat (unstable) [Error! Rotated Q has non-zero gradient (within 3sigma) EPICS will not be updated with these values]

y:bpmMovercal2009_2_24__8_28_4.mat

Mover settings: moveparams.aves=10; moveparams.steps=5; moveparams.range=100