Cavity A

BPM A Reference Position
Frequency /GHz 15.3099 14.9809
Internal Q 1235 1362
External Q 2156 2236
Loaded Q 790 866

BPM_A_SMITH.png

Cavity B

BPM A Reference Position
Frequency /GHz 15.182 14.980
Internal Q 1133 1338
External Q 1851 2341
Loaded Q 705 876

BPM_B_SMITH.png

Cavity C

BPM A Reference Position
Frequency /GHz 15.265 14.987
Internal Q 1212 1218
External Q 1885 2725
Loaded Q 740 866

BPM_C_SMITH.png

Cavity D

BPM A Reference Position
Frequency /GHz 15.327 14.983
Internal Q 1161 1259
External Q 1762 2110
Loaded Q 705 814

BPM_D_SMITH.png vna_trace.png

Unbrazed Parts

  • The dimensions of the unbrazed monopole cavity were measured and then tested with the VNA.
  • The dimesions were difficult to measure accurately but did not appear to differ from those in the metrology report.