Tags:
create new tag
view all tags

Full Down-Converter Measurements

Time Domain Summary

200nscoup.png 200nsphos.png noamp200.png tek00000.png

From top left: 20 dB coupler output after the mixer; time domain output after IF; output with no amplifier in IF; output with a more broadband amplifier from mini-circuits.

IF Time Domain

fullif_tek00000.png f3db_tek00000.png na_tek00000.png otha_tek00000.png fullif_tek00005.png 3dbdotha_tek00000.png

From top left: time domain signal from IF; with a 3 dB attenuator added after the amplifier; with no amplification; with the second amplifier; at an IF of 250 MHz; with the second amplifier and a 3 dB attenuator.

Physics WebpagesRHUL WebpagesCampus Connect • Royal Holloway, University of London, Egham, Surrey TW20 0EX; Tel/Fax +44 (0)1784 434455/437520

Topic revision: r1 - 20 Dec 2012 - FrankieCullinan

 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2023 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.