Charge Scans Done by Changing the Laser Attenuation

  • The attenuation of the laser was achieved with a quarter wave plate and a rotating polariser.

Filename Number of pulses Comments
ctf3cbpm_20130307_172243.dat 10 Charge scan picomotor 4000 no attenuation
ctf3cbpm_20130307_172306.dat 10 Charge scan picomotor 4100 no attenuation
ctf3cbpm_20130307_172329.dat 10 Charge scan picomotor 4200 no attenuation
ctf3cbpm_20130307_172350.dat 10 Charge scan picomotor 4300 no attenuation
ctf3cbpm_20130307_172407.dat 10 Charge scan picomotor 4400 no attenuation
ctf3cbpm_20130307_172424.dat 10 Charge scan picomotor 4500 no attenuation
ctf3cbpm_20130307_172440.dat 10 Charge scan picomotor 4600 no attenuation
ctf3cbpm_20130307_172456.dat 10 Charge scan picomotor 4700 no attenuation
ctf3cbpm_20130307_172511.dat 10 Charge scan picomotor 4800 no attenuation
ctf3cbpm_20130307_172529.dat 10 Charge scan picomotor 4900 no attenuation
ctf3cbpm_20130307_172544.dat 10 Charge scan picomotor 5000 no attenuation
ctf3cbpm_20130307_172601.dat 10 Charge scan picomotor 5100 no attenuation
ctf3cbpm_20130307_172617.dat 10 Charge scan picomotor 5200 no attenuation
ctf3cbpm_20130307_172640.dat 10 Charge scan picomotor 5300 no attenuation
ctf3cbpm_20130307_172656.dat 10 Charge scan picomotor 5400 no attenuation
ctf3cbpm_20130307_172713.dat 10 Charge scan picomotor 5500 no attenuation
ctf3cbpm_20130307_172733.dat 10 Charge scan picomotor 5600 no attenuation
ctf3cbpm_20130307_172748.dat 10 Charge scan picomotor 5700 no attenuation
ctf3cbpm_20130307_172809.dat 10 Charge scan picomotor 5800 no attenuation
ctf3cbpm_20130307_172829.dat 10 Charge scan picomotor 5900 no attenuation
ctf3cbpm_20130307_172852.dat 10 Charge scan picomotor 6000 no attenuation
ctf3cbpm_20130307_172918.dat 10 Charge scan picomotor 6100 no attenuation
ctf3cbpm_20130307_173030.dat 10 Charge scan picomotor 6100 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173049.dat 10 Charge scan picomotor 6200 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173105.dat 10 Charge scan picomotor 6300 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173124.dat 10 Charge scan picomotor 6400 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173140.dat 10 Charge scan picomotor 6500 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173155.dat 10 Charge scan picomotor 6600 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173211.dat 10 Charge scan picomotor 6700 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173225.dat 10 Charge scan picomotor 6800 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173243.dat 10 Charge scan picomotor 6900 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173300.dat 10 Charge scan picomotor 7000 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173317.dat 10 Charge scan picomotor 7100 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173335.dat 10 Charge scan picomotor 7200 x,y,ref att: 6,0,6
ctf3cbpm_20130307_173354.dat 10 Charge scan picomotor 7300 x,y,ref att: 6,0,6

  • Repeat

Filename Number of pulses Comments
ctf3cbpm_20130307_175626.dat 20 Charge scan picomotor 1000 no attenuation
ctf3cbpm_20130307_175646.dat 20 Charge scan picomotor 1100 no attenuation
ctf3cbpm_20130307_175708.dat 20 Charge scan picomotor 1200 no attenuation
ctf3cbpm_20130307_175729.dat 20 Charge scan picomotor 1300 no attenuation
ctf3cbpm_20130307_175750.dat 20 Charge scan picomotor 1400 no attenuation
ctf3cbpm_20130307_175812.dat 20 Charge scan picomotor 1500 no attenuation
ctf3cbpm_20130307_175835.dat 20 Charge scan picomotor 1600 no attenuation
ctf3cbpm_20130307_175856.dat 20 Charge scan picomotor 1700 no attenuation
ctf3cbpm_20130307_175920.dat 20 Charge scan picomotor 1800 no attenuation
ctf3cbpm_20130307_175947.dat 20 Charge scan picomotor 1900 no attenuation
ctf3cbpm_20130307_180008.dat 20 Charge scan picomotor 2000 no attenuation
ctf3cbpm_20130307_180029.dat 20 Charge scan picomotor 2100 no attenuation
ctf3cbpm_20130307_180053.dat 20 Charge scan picomotor 2200 no attenuation
ctf3cbpm_20130307_180115.dat 20 Charge scan picomotor 2300 no attenuation
ctf3cbpm_20130307_180144.dat 20 Charge scan picomotor 2400 no attenuation
ctf3cbpm_20130307_180956.dat 20 Charge scan picomotor 0000 no attenuation
ctf3cbpm_20130307_181016.dat 20 Charge scan picomotor 0100 no attenuation
ctf3cbpm_20130307_181038.dat 20 Charge scan picomotor 0200 no attenuation
ctf3cbpm_20130307_181058.dat 20 Charge scan picomotor 0300 no attenuation
ctf3cbpm_20130307_181120.dat 20 Charge scan picomotor 0400 no attenuation
ctf3cbpm_20130307_181144.dat 20 Charge scan picomotor 0500 no attenuation
ctf3cbpm_20130307_181203.dat 20 Charge scan picomotor 0600 no attenuation
ctf3cbpm_20130307_181226.dat 20 Charge scan picomotor 0700 no attenuation
ctf3cbpm_20130307_181250.dat 20 Charge scan picomotor 0800 no attenuation
ctf3cbpm_20130307_181311.dat 20 Charge scan picomotor 0900 no attenuation
ctf3cbpm_20130307_181331.dat 20 Charge scan picomotor 1000 no attenuation
ctf3cbpm_20130307_181355.dat 20 Charge scan picomotor 1100 no attenuation
ctf3cbpm_20130307_181417.dat 20 Charge scan picomotor 1200 no attenuation
ctf3cbpm_20130307_181439.dat 20 Charge scan picomotor 1300 no attenuation
ctf3cbpm_20130307_181505.dat 20 Charge scan picomotor 1400 no attenuation
ctf3cbpm_20130307_181544.dat 20 Charge scan picomotor 0000 no attenuation
ctf3cbpm_20130307_181608.dat 20 Charge scan picomotor 0050 no attenuation
ctf3cbpm_20130307_181632.dat 20 Charge scan picomotor 0100 no attenuation
ctf3cbpm_20130307_181656.dat 20 Charge scan picomotor 0150 no attenuation
ctf3cbpm_20130307_181721.dat 20 Charge scan picomotor 0200 no attenuation
ctf3cbpm_20130307_181743.dat 20 Charge scan picomotor 0250 no attenuation
ctf3cbpm_20130307_181809.dat 20 Charge scan picomotor 0300 no attenuation
ctf3cbpm_20130307_181830.dat 20 Charge scan picomotor 0350 no attenuation
ctf3cbpm_20130307_181855.dat 20 Charge scan picomotor 0400 no attenuation
ctf3cbpm_20130307_181919.dat 20 Charge scan picomotor 0450 no attenuation
ctf3cbpm_20130307_181948.dat 20 Charge scan picomotor 0500 no attenuation
ctf3cbpm_20130307_182010.dat 20 Charge scan picomotor 0550 no attenuation
ctf3cbpm_20130307_182035.dat 20 Charge scan picomotor 0600 no attenuation
ctf3cbpm_20130307_182100.dat 20 Charge scan picomotor 0650 no attenuation
ctf3cbpm_20130307_182124.dat 20 Charge scan picomotor 0700 no attenuation
ctf3cbpm_20130307_182147.dat 20 Charge scan picomotor 0750 no attenuation
ctf3cbpm_20130307_182211.dat 20 Charge scan picomotor 0800 no attenuation
ctf3cbpm_20130307_182234.dat 20 Charge scan picomotor 0850 no attenuation
ctf3cbpm_20130307_182258.dat 20 Charge scan picomotor 0900 no attenuation
ctf3cbpm_20130307_182319.dat 20 Charge scan picomotor 0950 no attenuation
ctf3cbpm_20130307_182344.dat 20 Charge scan picomotor 1000 no attenuation

wcmcscan.png

Saturation Test of the Electronics

  • The same technique was used to find the saturation of the electronics with a longer pulse length

Filename Number of pulses Comments
ctf3cbpm_20130307_185726.dat 20 satturation via charge pico 2000 no att
ctf3cbpm_20130307_185747.dat 20 satturation via charge pico 2100 no att
ctf3cbpm_20130307_185811.dat 20 satturation via charge pico 2200 no att
ctf3cbpm_20130307_185832.dat 20 satturation via charge pico 2300 no att
ctf3cbpm_20130307_185853.dat 20 satturation via charge pico 2400 no att
ctf3cbpm_20130307_185914.dat 20 satturation via charge pico 2500 no att
ctf3cbpm_20130307_185939.dat 20 satturation via charge pico 2600 no att
ctf3cbpm_20130307_185958.dat 20 satturation via charge pico 2700 no att
ctf3cbpm_20130307_190020.dat 20 satturation via charge pico 2800 no att
ctf3cbpm_20130307_190046.dat 20 satturation via charge pico 2900 no att
ctf3cbpm_20130307_190107.dat 20 satturation via charge pico 3000 no att
ctf3cbpm_20130307_190127.dat 20 satturation via charge pico 3100 no att
ctf3cbpm_20130307_190148.dat 20 satturation via charge pico 3200 no att
ctf3cbpm_20130307_190208.dat 20 satturation via charge pico 3300 no att
ctf3cbpm_20130307_190228.dat 20 satturation via charge pico 3400 no att
ctf3cbpm_20130307_190251.dat 20 satturation via charge pico 3500 no att
ctf3cbpm_20130307_190312.dat 20 satturation via charge pico 3600 no att

Edit | Attach | Watch | Print version | History: r4 < r3 < r2 < r1 | Backlinks | Raw View | Raw edit | More topic actions

Physics WebpagesRHUL WebpagesCampus Connect • Royal Holloway, University of London, Egham, Surrey TW20 0EX; Tel/Fax +44 (0)1784 434455/437520

Topic revision: r4 - 04 Apr 2013 - FrankieCullinan

 
This site is powered by the TWiki collaboration platform Powered by PerlCopyright © 2008-2023 by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding RHUL Physics Department TWiki? Send feedback