Cavity Sensitivity Estimates
Position Cavity
The dipole mode sensitivity was estimated from the following formula, the measured external quality factor of 617 and R/Q from simulation in several codes, of which CST and GdfidL use a hexahedral mesh while Ace3p uses a tetrahedral mesh:
Reference Cavity
The measured external quality factor of the reference cavity is 203.
Electronics Chain Propagation
Electronics gain/dB |
5 |
Cable loss/dB |
-2.6 |
Position cavity attenuation/dB |
6 |
Reference cavity attenuation/dB |
20 |
|
Position signal (offset=1mm, charge=1nC) |
Reference signal (Charge=1nC) |
Location |
Volts |
dBm |
Volts |
dBm |
Cavity out |
8.3 |
31.4 |
52.0 |
47.3 |
Electronics in |
4.2 |
25.4 |
5.2 |
27.3 |
Electronics out |
7.4 |
30.4 |
9.2 |
32.3 |
Digitiser in |
5.5 |
27.8 |
6.9 |
29.7 |
- Position scale factor: 1.25 mm